Science-advisor
REGISTER info/FAQ
Login
username
password
     
forgot password?
register here
 
Research articles
  search articles
  reviews guidelines
  reviews
  articles index
My Pages
my alerts
  my messages
  my reviews
  my favorites
 
 
Stat
Members: 3645
Articles: 2'503'724
Articles rated: 2609

23 April 2024
 
  » pubmed » pmid16383741

 Article overview


Thermocapillary transport of energy during water evaporation
Fei Duan ; V K Badam ; F Durst ; C A Ward ;
Date 31 Oct 2005
Journal Phys Rev E, 72 (5 Pt 2), 056303
AbstractWhen evaporation occurs at a spherical water-vapor interface maintained at the circular mouth of a small funnel, studies of the energy transport have indicated that thermal conduction alone does not provide enough energy to evaporate the liquid at the observed rate. If the Gibbs model of the interface is adopted and the "surface-thermal capacity" is assigned a value of 30.6+/-0.8 kJ/(m2 K), then for evaporation experiments with the interfacial temperature in the range -10 degrees C< or =TLV< or =3.5 degrees C and Marangoni number (Ma) in the range 100<Ma<22,000, it was found that if energy transport by both thermocapillary convection and thermal conduction were taken into account, conservation of energy was fully satisfied. The question addressed herein is whether the assigned value of the surface-thermal capacity is an ad hoc empirical parameter or a property of the water-vapor interface that can be used in other circumstances. Accordingly, a series of experiments has been conducted in which water evaporated at cylindrical interfaces that were, on average, 4.4 times larger in area than that of the spherical interfaces used to measure the surface-thermal capacity initially. It is shown that using the value of the surface-thermal capacity determined at a spherical interface, the energy transported by thermocapillary convection and thermal conduction at a cylindrical interface is sufficient to evaporate the liquid at the observed rate. Knowing the value of the surface-thermal capacity also allows the local evaporation flux to be calculated from the measured temperature profiles in the liquid and vapor phases. The calculated local evaporation flux can then be used with statistical rate theory to calculate the vapor-phase pressure along the interface. The predicted mean vapor-phase pressure is in close agreement with that measured, and the predicted pressure gradient is consistent with that expected when thermocapillary convection is present.
Source PubMed, pmid16383741
Services Forum | Review | Favorites   
 
Visitor rating: did you like this article? no 1   2   3   4   5   yes

No review found.
 Did you like this article?

This article or document is ...
important:
of broad interest:
readable:
new:
correct:
Global appreciation:

  Note: answers to reviews or questions about the article must be posted in the forum section.
Authors are not allowed to review their own article. They can use the forum section.

browser Mozilla/5.0 AppleWebKit/537.36 (KHTML, like Gecko; compatible; ClaudeBot/1.0; +claudebot@anthropic.com)






ScienXe.org
» my Online CV
» Free


News, job offers and information for researchers and scientists:
home  |  contact  |  terms of use  |  sitemap
Copyright © 2005-2024 - Scimetrica