Stat |
Members: 3645 Articles: 2'500'096 Articles rated: 2609
18 April 2024 |
|
| | | |
|
Article overview
| |
|
Self-paced brain-computer interface control of ambulation in a virtual reality environment | Po T. Wang
; Christine E. King
; Luis A. Chui
; An H. Do
; Zoran Nenadic
; | Date: |
30 Aug 2012 | Abstract: | Objective: Spinal cord injury (SCI) often leaves affected individuals unable
to ambulate. Electroencephalogramme (EEG) based brain-computer interface (BCI)
controlled lower extremity prostheses may restore intuitive and able-body-like
ambulation after SCI. To test its feasibility, the authors developed and tested
a novel EEG-based, data-driven BCI system for intuitive and self-paced control
of the ambulation of an avatar within a virtual reality environment (VRE).
Approach: Eight able-bodied subjects and one with SCI underwent the following
10-min training session: subjects alternated between idling and walking
kinaesthetic motor imageries (KMI) while their EEG were recorded and analysed
to generate subject-specific decoding models. Subjects then performed a
goal-oriented online task, repeated over 5 sessions, in which they utilised the
KMI to control the linear ambulation of an avatar and make 10 sequential stops
at designated points within the VRE.
Main results: The average offline training performance across subjects was
77.2 +/- 9.5%, ranging from 64.3% (p = 0.00176) to 94.5% (p = 6.26*10^-23),
with chance performance being 50%. The average online performance was 8.4 +/-
1.0 (out of 10) successful stops and 303 +/- 53 sec completion time (perfect =
211 sec). All subjects achieved performances significantly different than those
of random walk (p < 0.05) in 44 of the 45 online sessions.
Significance: By using a data-driven machine learning approach to decode
users’ KMI, this BCIVRE system enabled intuitive and purposeful self-paced
control of ambulation after only a 10-minute training. The ability to achieve
such BCI control with minimal training indicates that the implementation of
future BCI-lower extremity prosthesis systems may be feasible. | Source: | arXiv, 1208.6057 | Services: | Forum | Review | PDF | Favorites |
|
|
No review found.
Did you like this article?
Note: answers to reviews or questions about the article must be posted in the forum section.
Authors are not allowed to review their own article. They can use the forum section.
browser claudebot
|
| |
|
|
|