| | |
| | |
Stat |
Members: 3645 Articles: 2'504'585 Articles rated: 2609
24 April 2024 |
|
| | | |
|
Article overview
| |
|
Cosmic Ray Measurements with LOPES: Status and Recent Results (ARENA 2012) | F.G. Schröder
; W.D. Apel
; J.C. Arteaga
; L. Bähren
; K. Bekk
; M. Bertaina
; P.L. Biermann
; J. Blümer
; H. Bozdog
; I.M. Brancus
; A. Chiavassa
; K. Daumiller
; V. de Souza
; F. Di Pierro
; P. Doll
; R. Engel
; H. Falcke
; B. Fuchs
; D. Fuhrmann
; H. Gemmeke
; C. Grupen
; A. Haungs
; D. Heck
; J.R. Hörandel
; A. Horneffer
; D. Huber
; T. Huege
; P.G. Isar
; K.-H. Kampert
; D. Kang
; O. Krömer
; J. Kuijpers
; K. Link
; P. Luczak
; M. Ludwig
; H.J. Mathes
; M. Melissas
; C. Morello
; J. Oehlschläger
; N. Palmieri
; T. Pierog
; J. Rautenberg
; H. Rebel
; M. Roth
; C. Rühle
; A. Saftoiu
; H. Schieler
; A. Schmidt
; O. Sima
; G. Toma
; G.C. Trinchero
; A. Weindl
; J. Wochele
; J. Zabierowski
; J.A. Zensus
; | Date: |
11 Jan 2013 | Abstract: | LOPES is a digital antenna array at the Karlsruhe Institute of Technology,
Germany, for cosmic-ray air-shower measurements. Triggered by the co-located
KASCADE-Grande air-shower array, LOPES detects the radio emission of air
showers via digital radio interferometry. We summarize the status of LOPES and
recent results. In particular, we present an update on the reconstruction of
the primary-particle properties based on almost 500 events above 100 PeV. With
LOPES, the arrival direction can be reconstructed with a precision of at least
0.65{deg}, and the energy with a precision of at least 20 %, which, however,
does not include systematic uncertainties on the absolute energy scale. For
many particle and astrophysics questions the reconstruction of the atmospheric
depth of the shower maximum, Xmax, is important, since it yields information on
the type of the primary particle and its interaction with the atmosphere.
Recently, we found experimental evidence that the slope of the radio lateral
distribution is indeed sensitive to the longitudinal development of the air
shower, but unfortunately, the Xmax precision at LOPES is limited by the high
level of anthropogenic radio background. Nevertheless, the developed methods
can be transferred to next generation experiments with lower background, which
should provide an Xmax precision competitive to other detection technologies. | Source: | arXiv, 1301.2557 | Services: | Forum | Review | PDF | Favorites |
|
|
No review found.
Did you like this article?
Note: answers to reviews or questions about the article must be posted in the forum section.
Authors are not allowed to review their own article. They can use the forum section.
browser Mozilla/5.0 AppleWebKit/537.36 (KHTML, like Gecko; compatible; ClaudeBot/1.0; +claudebot@anthropic.com)
|
| |
|
|
|
| News, job offers and information for researchers and scientists:
| |