The CDEX-1 1 kg Point-Contact Germanium Detector for Low Mass Dark Matter Searches
Ke-Jun Kang ; Qian Yue ; Yu-Cheng Wu ; Jian-Ping Cheng ; Yuan-Jing Li ; Yang Bai ; Yong Bi ; Jian-Ping Chang ; Nan Chen ; Ning Chen ; Qing-Hao Chen ; Yun-Hua Chen ; You-Chun Chuang ; Zhi Dend ; Qiang Du ; Hui Gong ; Xi-Qing Hao ; Qing-Ju He ; Xin-Hui Hu ; Han-Xiong Huang ; Teng-Rui Huang ; Hao Jiang ; Hau-Bin Li ; Jian-Min Li ; Jin Li ; Jun Li ; Xia Li ; Xin-Ying Li ; Xue-Qian Li ; Yu-Lan Li ; Heng-Ye Liao ; Fong-Kay Lin ; Shin-Ted Lin ; Shu-Kui Liu ; Lan-Chun Lv ; Hao Ma ; Shao-Ji Mao ; Jian-Qiang Qin ; Jie Ren ; Jing Ren ; Xi-Chao Ruan ; Man-Bin Shen ; Lakhwinder Singh ; Manoj Kumar Singh ; Arun Kumar Soma ; Jian Su ; Chang-Jian Tang ; Chao-Hsiung Tseng ; Ji-Min Wang ; Li Wang ; Qing Wang ; Tsz-King Henry Wong ; Shi-Yong Wu ; Wei Wu ; Yu-Cheng Wu ; Hao-Yang Xing ; Yin Xu ; Tao Xue ; Li-Tao Yang ; Song-Wei Yang ; Nan Yi ; Chun-Xu Yu ; Hao Yu ; Xun-Zhen Yu ; Xiong-Hui Zeng ; Zhi Zeng ; Lan Zhang ; Yun-Hua Zhang ; Ming-Gang Zhao ; Wei Zhao ; Su-Ning Zhong ; Zu-Ying Zhou ; Jing-Jun Zhu ; Wei-Bin Zhu ; Xue-Zhou Zhu ; Zhong-Hua Zhu ;
Date 2 May 2013
AbstractThe CDEX Collaboration has been established for direct detection of light dark matter particles, using ultra-low energy threshold p-type point-contact germanium detectors, in China JinPing underground Laboratory (CJPL). The first 1 kg point-contact germanium detector with a sub-keV energy threshold has been tested in a passive shielding system located in CJPL. The outputs from both the point-contact p+ electrode and the outside n+ electrode make it possible to scan the lower energy range of less than 1 keV and at the same time to detect the higher energy range up to 3 MeV. The outputs from both p+ and n+ electrode may also provide a more powerful method for signal discrimination for dark matter experiment. Some key parameters, including energy resolution, dead time, decay times of internal X-rays, and system stability, have been tested and measured. The results show that the 1 kg point-contact germanium detector, together with its shielding system and electronics, can run smoothly with good performances. This detector system will be deployed for dark matter search experiments.
Source arXiv, 1305.0401
Services Forum | Review | PDF | Favorites   
 
Visitor rating: did you like this article? no 1   2   3   4   5   yes

No review found.
 Did you like this article?

This article or document is ...
important:
of broad interest:
readable:
new:
correct:
Global appreciation:

  Note: answers to reviews or questions about the article must be posted in the forum section.
Authors are not allowed to review their own article. They can use the forum section.

browser Mozilla/5.0 AppleWebKit/537.36 (KHTML, like Gecko; compatible; ClaudeBot/1.0; +claudebot@anthropic.com)






ScienXe.org
» my Online CV
» Free


News, job offers and information for researchers and scientists:
home  |  contact  |  terms of use  |  sitemap
Copyright © 2005-2024 - Scimetrica