Science-advisor
REGISTER info/FAQ
Login
username
password
     
forgot password?
register here
 
Research articles
  search articles
  reviews guidelines
  reviews
  articles index
My Pages
my alerts
  my messages
  my reviews
  my favorites
 
 
Stat
Members: 3645
Articles: 2'500'096
Articles rated: 2609

19 April 2024
 
  » arxiv » 1910.4955

 Article overview


The High Energy X-ray telescope (HE) onboard the Insight-HXMT astronomy satellite
C.Z. Liu ; Y.F. Zhang ; X.F. Li ; X.F. Lu ; Z. Chang ; Z.W. Li ; A.Z. Zhang ; Y.J. Jin ; H.M. Yu ; Z. Zhang ; M.X. Fu ; Y.B. Chen ; J.F. Ji ; Y.P. Xu ; J.K. Deng ; R.C. Shang ; G.Q. Liu ; F.J. Lu ; S.N. Zhang ; Y.W. Dong ; T.P. Li ; M. Wu ; Y.G. Li ; H.Y.Wang ; B.B. Wu ; Y.J. Zhang ; Z. Zhang ; S.L. Xiong ; Y. Liu ; S. Zhang ; H.W. Liu ; Y.R. Yang ; F. Zhang ;
Date 11 Oct 2019
AbstractThe Insight-Hard X-ray Modulation Telescope (Insight-HXMT) is a broad band X-ray and gamma-ray (1-3000 keV) astronomy satellite. The High Energy X-ray telescope (HE) is one of its three main telescopes. The main detector plane of HE is composed of 18 NaI(Tl)/CsI(Na) phoswich detectors, where NaI(Tl) serves as primary detector to measure ~ 20-250 keV photons incident from the field of view (FOV) defined by the collimators, and CsI(Na) is used as an active shield detector to NaI(Tl) by pulse shape discrimination. CsI(Na) is also used as an omnidirectional gamma-ray monitor. The HE collimators have a diverse FOV: 1.1{deg}x 5.7{deg} (15 units), 5.7{deg}x 5.7{deg} (2 units) and blocked (1 unit), thus the combined FOV of HE is about 5.7{deg}x 5.7{deg}. Each HE detector has a diameter of 190 mm, resulting in the total geometrical area of about 5100 cm_2. The energy resolution is ~15% at 60 keV. The timing accuracy is better than 10 {mu}s and dead-time for each detector is less than 10 {mu}s. HE is devoted to observe the spectra and temporal variability of X-ray sources in the 20-250 keV band either by pointing observations for known sources or scanning observations to unveil new sources, and to monitor the gamma-ray sky in 0.2-3 MeV. This paper presents the design and performance of the HE instruments. Results of the on-ground calibration experiments are also reported.
Source arXiv, 1910.4955
Services Forum | Review | PDF | Favorites   
 
Visitor rating: did you like this article? no 1   2   3   4   5   yes

No review found.
 Did you like this article?

This article or document is ...
important:
of broad interest:
readable:
new:
correct:
Global appreciation:

  Note: answers to reviews or questions about the article must be posted in the forum section.
Authors are not allowed to review their own article. They can use the forum section.

browser claudebot






ScienXe.org
» my Online CV
» Free


News, job offers and information for researchers and scientists:
home  |  contact  |  terms of use  |  sitemap
Copyright © 2005-2024 - Scimetrica